热线:021-56640700/17317611498

产品目录

Products

范先生

021-56640700

17317611498

点击这里给我发消息

产品中心

您的位置:网站首页 > 产品中心 > 实验室常规耗材 > 美国Hausser细胞计数板 > 4000、4001美国Hausser细胞计数板

美国Hausser细胞计数板

简要描述:

美国Hausser细胞计数板(Nageotte Counting Chamber):亮线型,常用于单采血小板中的残留白细胞的计数。池深:0.5mm。提供两种:一种H型,中间有沟隔开为两计数区(货号4000),一种没有沟槽(4001)

发邮件给我们:2640810570@qq.com

分享到:
索取报价
品牌其他品牌产地类别进口
应用领域医疗卫生

美国Hausser细胞计数板(Nageotte Counting Chamber):亮线型,常用于单采血小板中的残留白细胞的计数。池深:0.5mm。提供两种:一种H型,中间有沟隔开为两计数区(货号4000),一种没有沟槽(4001)美国Hausser scientific血球计数板,霍华德霉菌计数板,准确计算白细胞、红细胞、血小板、组织培养细胞、细菌和精子The Hausser Nageotte Bright-Line Hemacytometer allows one to manually count low leukocyte concentrations below the capabilities of a standard Hemacytometer. The Nageotte contains two gridded counting areas each containing 40 rectangular areas. Total volume of each grid is 50 mL for a total volume of 100 mL per Nageotte. The Nageotte can accuray measure down to 0.1 cell/mL (100 cell/ml). Cell Depth is 0.5mm .

美国Hausser细胞计数板

Available with an H-shaped moat(catalog#4000) that separates the two gridded areas or without a moat (catalog#4001). The Nageotte Chamber comes with two reusable cover slips(30mm X 33mm X 0.5mm) and 1/2 oz (approx. 35 pcs.) of disposable cover slips (30mm X 33mm X 0.15mm). PROCESS: Counting low levels of white cells in white cell-reduced plaetcomponents.BACKGROUND: Determination of the white cell (WBC) count in WBC-reduced plaet components requires methods that have a detection limit in the range of approximay 5.0 x 10(2) to 5.0 x 10(4) per mL.STUDY DESIGN AND METHODS: With a 50-microL Nageotte hemocytometer and bright-field microscopy (200x magnification), studies were conducted to develop and validate a method that could be used routinely with filtered and apheresis-harvested plaets. A 1-in-5 dilution of sample with a commercially available blood-diluting fluid was used because, with a lower (1-in-2) dilution, the observed number of WBCs was substantially less than the number expected at relatively high plaet counts (> 1.9 x 10(9)/mL). RESULTS: The observed and expected WBC counts in WBC-reduced plaet samples correlated well at levels between approximay 5 and 1100 WBCs per counting area (5.0 x 10(2)-1.1 x 10(5)/mL). At levels of more than 300 to 400 WBCs per counting area, accurate counts were obtained when 10 of the 40 rectangles were counted.

留言框

  • 产品:

  • 留言内容:

  • 您的单位:

  • 您的姓名:

  • 联系电话:

  • 常用邮箱:

  • 详细地址:

  • 省份:

  • 验证码:

    请输入计算结果(填写阿拉伯数字),如:三加四=7

上海涸宇机电科技有限公司

Copyright @ 上海涸宇机电科技有限公司 All rights reserved. 技术支持:化工仪器网 GoogleSitemap 管理登陆

 
QQ在线咨询
范先生
销售电话:
021-56640700
17317611498
点击这里给我发消息